(1) when multiple groups are used in parallel, one group of wires is connected in reverse, resulting in diode reverse breakdown;
(2) repeated shielding in a short period of time - no shielding, the reverse and forward conversion leads to thermal breakdown failure;
(3) external electrostatic generated beyond the diode range, resulting in breakdown.